TIG 3200 AC/DC
17
3.6.4. ACTIVATION SYSTEM TENSION REDUCTION (VRD)
This protection system for the welding personnel allows arc ignition in electrode welding with a safety vacuum voltage.
Confirmation question for activation is required:
KEY
ACTION
P5
Cancel
P6
Confirm
3.6.5. ACTION 2nd PUSH BUTTON TORCH.
When using torches with a double pushbutton system, we can choose the action controlled by the secondary pushbutton:
REGULATION E2
DESCRIPTION
Correction
We work on the correction value selected in the equipment. e.g: pulsed frequency.
Program
Increases or decreases per every pulse 1 program listing available programs.
3.6.6. SELECTING EFFECTIVE POWER MEASUREMENT.
We define the activation current reading effectively system in the welding phase.
REGULATION E2
DESCRIPTION
ON
The computer makes the reading of I2 real each moment of welding and it reflects on display.
OFF
Display indicates the rated current.