P a g e
|
14
Figure 12: Equipment grounding of the Top Flashing using DynoBond™ Clips
Figure 13: Connecting the DynoBond™ Clip to the Grounding Wire using S -8 S plit-Bolt Connector
#12 or #10 AWG
Bare Solid Copper
Grounding Wire
Dynobond™ Clip
S-8 Split-Bolt
Connector
Figure 11: Connecting the S olar Module Assembly to the grounding path
Bare Copper Wire
Top Flashing
WEEB
®
Terminal
Screw