Step 7c: Position the Top Flashings…
Position the top flashings so that they are centered with the solar
module assembly below. The top metal flashing hooks into the inner top flashing (Figure 58).
Step 7d: Install the Grounding Clips on the Top Flashings...
Each top flashing and top corner flashing
must be grounded with the DynoBond™ clips
.
The DynoBond™ clips are designed to penetrate
the finishing coat on the edge of the top flashing. Using a hammer to lightly tap the clip into
place makes installation easier (Figure 59). The clips are attached to each other by a coated
copper wire that electrically bonds the top flashing parts together. Adjacent top flashings
share the same DynoBond™ clip.
Figure 58: Positioning the Top Flashing
Figure 59: Install the Grounding Clip on the Top Flashing
Dynobond™
Grounding Clips
Top Flashing
1
2
3