60
For
broadcasting
messages to multiple modems, set the
destination address
to
255. In this case, the modem
retransmits
the message the number of times of the
Retransmission count
plus 1, and then it will return “P0”.
In case the
global addressing command
is issued to plural modems connected by
RS485 multi-dropping interface, the transmission stops when any modem outputs
“P0”, “N2” or “N3”
response
to the RS485 line.
Example
>@TXR100002HELLO
CR/LF
: transmits HELLO from station 001 to station 002 through
repeater
100
<P1
CR/LF
: data being transmitted
<P2
CR/LF
: data packet reached to
repeater
<P0
CR/LF
: data transmission succeeded
Notes
Set the
message length
to 255 byte or less. The
message length
exceeding 255
byte will be
command error
.
When the same character as the
terminator
(CR/LF) is contained in a message, the
modem distinguishes it as the end of a command and ignore the subsequent data. In
such a case, use
TBR command
.
In
broadcast transmission
, the receiving result of the
destination station
cannot
be confirmed at the sender side.
TXT
Transmit Text Data
Syntax
TXT [destination address]{Local Station Address}[message]
destination address
: address of
destination station
(000 to A23)
Local Station Address
:
local station address
for
485 mode
(000 to A22).
message
: any text data (255 or less)
Response
P0
: data transmission succeeded
P1
: command accepted, data being transmitted
N0
:
command error
(Except
485 mode
)
N1
: data transmission failed - no
response
from the
destination station
N2
: data transmission failed -
destination station
is in the
reception disabled state
N3
: data transmission failed –
destination station
cannot receive because its receive
buffer is full.
Function
Transmits text data in the
packet transmission mode
.
Any message length between 1 to 255 bytes is accepted. The completion of data
input is recognized by the
terminator
(CR/LF).
For
broadcasting
messages to multiple modems, set the
destination address
to
255. In this case, the modem will
retransmit
the message the number of times of
the
Retransmission count
plus 1, and then it will return “P0”.
In case the
global addressing command
is issued to plural modems connected by
RS485 multi-dropping interface, the transmission stops when any modem outputs
“P0”, “N2” or “N3”
response
to the RS485 line.
Example
>@TXT002HELLO
CR/LF
: transmits HELLO from station 001 to station 002
<P1
CR/LF
: data being transmitted
Summary of Contents for FDL01TU
Page 14: ......
Page 15: ...1 1 SECTION 1 INTRODUCTION ...
Page 19: ...5 2 SECTION 2 SYSTEM INSTALLATION ...
Page 25: ...11 3 SECTION 3 SYSTEM OPERATION ...
Page 34: ...20 ...
Page 35: ...21 4 SECTION 4 FUNCTION CONTROL METHODS ...
Page 41: ...27 5 SECTION 5 MEMORY REGISTER DESCRIPTION ...
Page 56: ...42 ...
Page 57: ...43 6 SECTION 6 COMMAND SET DESCRIPTION ...
Page 76: ...62 ...
Page 77: ...Futaba Corporation Rev 020323 01 7 APPENDIX 7 SECTION ...
Page 82: ...68 7 4 Dimensions 7 4 1 FDL01TU 7 4 2 Communication Cable ...