31
REG11: Retransmission Count
[default value: 32H]
•
Sets the maximum
number of packet retransmission
attempts. Valid values are 000
to 255.
•
When retransmission exceeds the
retransmission count
(
retransmission count
plus
one), the modem outputs an
error response
to the terminal equipment.
REG12: Roaming Threshold
[default value: 50H]
•
At the time to set the
frequency roaming
(
REG19:bit 2
is 1), set the
receiving
strength threshold of the radio beacon
which starts scanning frequency.
•
Set the value of the desired
radio beacon strength threshold
represented in dBm
excluding the minus sign, e.g., set to “080” to search the next master station when the
radio beacon strength
becomes below –80 dBm.
REG13: Buffer Data Timeout
[default value: 1EH]
•
Valid values are 000 to 255, representing seconds in 1 s increments.
REG14: Command Input Timeout
[default value: 32H]
•
Sets the character
input timeout interval for command input
. It is used
as the
timeout
between the
command header
and the character following it and between
each character of the command.
•
At the timeout, the modem operation transits from
command-input-state
to
data-
wait-state
.
•
Valid values are 000 to 255, representing tenths of seconds in 0.1 second increments.
(Set an integer value equal to ten times the number of seconds desired.)
•
A setting of 000 disables this
timeout function
REG15: Command Recognition Interval
[default value: 00H]
•
When a message data contains a
command header
character (in case of binary data
or data in two-byte Chinese characters), data following the
command header
character will be interpreted as a command, the message does not transmit properly.
•
Sets the necessary vacant duration
time interval
to discriminate between ordinary
data character and a
command header
character. Input a command after a longer
interval than
time interval
setting.
•
Valid values are 0.1 to 25.4 sec., representing tenths of seconds in 0.1 second
increments. (Set an integer value equal to ten times the number of seconds desired.)
•
When set to 000, the
command header
is recognized at any time, and when set to
255, all
command header
character are ignored.
Summary of Contents for FDL01TU
Page 14: ......
Page 15: ...1 1 SECTION 1 INTRODUCTION ...
Page 19: ...5 2 SECTION 2 SYSTEM INSTALLATION ...
Page 25: ...11 3 SECTION 3 SYSTEM OPERATION ...
Page 34: ...20 ...
Page 35: ...21 4 SECTION 4 FUNCTION CONTROL METHODS ...
Page 41: ...27 5 SECTION 5 MEMORY REGISTER DESCRIPTION ...
Page 56: ...42 ...
Page 57: ...43 6 SECTION 6 COMMAND SET DESCRIPTION ...
Page 76: ...62 ...
Page 77: ...Futaba Corporation Rev 020323 01 7 APPENDIX 7 SECTION ...
Page 82: ...68 7 4 Dimensions 7 4 1 FDL01TU 7 4 2 Communication Cable ...