![Furuno SFD-1010 Operator'S Manual Download Page 81](http://html1.mh-extra.com/html/furuno/sfd-1010/sfd-1010_operators-manual_2350505081.webp)
2.24.10 How to set a collision alert (CPA/TCPA alert)
To avoid collision with other ships, preset a threshold for CPA (Closest Point of
Approach to own ship by other ships) and TCPA (Time to Closest Point of Approach). If
both the CPA and TCPA of a tracking target becomes smaller than these two thresholds,
the target is recognized as a dangerous target (lit in red) and an alert message appears
simultaneously in the “ALERT LIST” window. If both the CPA and TCPA of a sleeping
target becomes smaller than the thresholds, the target is automatically activated to
become a dangerous target.
To silence the aural alarm and erase the alert message, press any key on the key pad.
The dangerous target remains displayed until the dangerous state is removed.
How to set the CPA threshold
Touch control:
1.
Press the
MENU/ESC
key to open [MENU].
2.
Tap [ALERT SETTINGS].
3.
Tap [CPA].
The [Off]/[0.5NM]/[1NM]/[2NM]/[3NM]/[5NM]/[6NM] selection box appears.
4.
Tap [Off]/[0.5NM]/[1NM]/[2NM]/[3NM]/[5NM]/[6NM].
5.
Tap [x] on the title bar to close [MENU].
Key control:
1.
Press the
MENU/ESC
key to open [MENU].
2.
Select [ALERT] with the arrow keys, then press the
ENTER
key.
3.
Select [CPA] with the arrow keys, then press the
ENTER
key.
The [Off]/[0.5NM]/[1NM]/[2NM]/[3NM]/[5NM]/[6NM] selection box appears.
4.
Select [Off]/[0.5NM]/[1NM]/[2NM]/[3NM]/[5NM]/[6NM] with the arrow keys, then
press the
ENTER
key.
5.
Press the
MENU/ESC
key to close [MENU].
How to set the TCPA threshold
Touch control:
1.
Press the
MENU/ESC
key to open [MENU].
2.
Tap [ALERT SETTINGS].
3.
Tap [TCPA].
The [30 s]/[1 min]/[2 min]/[3 min]/[4 min]/[5 min]/6 min]/[12 min] selection box
appears.
2-47
2
.
RADAR