3. SETTINGS
3-8
3.6
Other Setting Menus for Antenna Unit
3.6.1
How to reset the sensor
You can reset the sensor (antenna unit) when experiencing antenna trouble.
1. Press the
MENU ESC
key to open the main menu.
2. Select [6 Sensor Setting]
then [4 Other].
3. Select [1 App Reset].
The confirmation message appears.
4. Select [1 Yes]. The sensor restarts.
3.6.2
How to clear the sensor settings
Note:
This function is for a serviceman.
You can clear the sensor (antenna sensor) settings when experiencing antenna trou-
ble.
1. Press the
MENU ESC
key to open the main menu.
2. Select [6 Sensor Setting] then [4 Other].
3. Select [2 Clear Setting]. The confirmation message appears.
4. Select [1 Yes]. The message "Processing..." appears on the screen then the sen-
sor settings are cleared.
5. Turn the power off then on.
3.6.3
How to set the time for dead reckoning
You can set the dead reckoning interval to use with the internal rate gyro sensor to
calculate bearing when the GNSS signal is lost.
1. Press the
MENU ESC
key to open the main menu.
2. Select [6 Sensor Setting] then [4 Other].
3. Select [3 Dead Reckoning Time].
4. Select [1 1 min], [2 2 min], [3 3 min], [4 4 min] or [5 5 min].
5. Press the
MENU ESC
key to close the main menu.
Summary of Contents for GS-100
Page 1: ...SATELLITE SPEED LOG GS 100 OPERATOR S MANUAL www furuno com Model ...
Page 14: ...EQUIPMENT LISTS xii This page is intentionally left blank ...
Page 54: ...5 ALERTS 5 8 This page is intentionally left blank ...
Page 78: ...7 MAINTENANCE TROUBLESHOOTING 7 10 This page is intentionally left blank ...
Page 118: ...AP 10 APPENDIX 3 TIME DIFFERENCES ...
Page 147: ...13 Feb 2014 H MAKI D 1 ...
Page 148: ...13 Feb 2014 H MAKI D 2 ...
Page 149: ...13 Feb 2014 H MAKI D 3 ...
Page 150: ...D 4 24 Jan 2018 H MAKI ...
Page 151: ...13 Feb 2014 H MAKI D 5 ...
Page 152: ...D 6 ...
Page 153: ...18 Dec 2012 Y NISHIYAMA D 7 ...
Page 157: ......