![Furuno GS-100 Operator'S Manual Download Page 137](http://html.mh-extra.com/html/furuno/gs-100/gs-100_operators-manual_2349656137.webp)
AP-29
APPENDIX 10 DISPLAY FOR DS-600
The display of data received from a GS-100 and DS-60 can be switched on the sub display
DS-600.
Installation
The signals from GS-100 and DS-60 are directly output to the display unit DS-600. Connect the
cables as shown in the figure below.
• Connect the cable between DATA1 port of the display unit GS-1002 and the TB3 port of the
display unit DS-600.
• Connect the cable between TB1/TB2 port of the display unit DS-600 and the TB10 or TB11 port
of the distributor unit DS-610.
For details, see the Installation manual for DS-60.
2 1
2 1
3
4
5
6
2 1
3
4
TB1
TTYCS-4
TB4
TB2
TB3
IV-1.25 sq
TTYCS-1
Display Unit DS-600
To DATA1 port of Display Unit GS-1002
To TB10 or TB11 port of Distributor Unit DS-610
100
7
35
100
7
35
M4
x1
TTYCS-4 (TB1/2, for distributor)
Arbitrary length
Sheath
Vinyl tape
Wind the shield.
Vinyl tape
TTYCS-1 (TB3, for GS-1002)
Arbitrary length
Sheath
Vinyl tape
Vinyl tape
Wind the shield.
Summary of Contents for GS-100
Page 1: ...SATELLITE SPEED LOG GS 100 OPERATOR S MANUAL www furuno com Model ...
Page 14: ...EQUIPMENT LISTS xii This page is intentionally left blank ...
Page 54: ...5 ALERTS 5 8 This page is intentionally left blank ...
Page 78: ...7 MAINTENANCE TROUBLESHOOTING 7 10 This page is intentionally left blank ...
Page 118: ...AP 10 APPENDIX 3 TIME DIFFERENCES ...
Page 147: ...13 Feb 2014 H MAKI D 1 ...
Page 148: ...13 Feb 2014 H MAKI D 2 ...
Page 149: ...13 Feb 2014 H MAKI D 3 ...
Page 150: ...D 4 24 Jan 2018 H MAKI ...
Page 151: ...13 Feb 2014 H MAKI D 5 ...
Page 152: ...D 6 ...
Page 153: ...18 Dec 2012 Y NISHIYAMA D 7 ...
Page 157: ......