8. INSTALLATION
8-23
8.3.8
Alert mode
1. Press the
MENU ESC
key to open the main menu.
2. Select [3 Alert] then [2 Mode].
Note:
This menu is for a serviceman.
3. Select [1 Alert I/F 1], [2 Alert I/F 2] or [3 Legacy]. For [1 Alert I/F 1] or [2 Alert I/F
2], go to step 6. For [3 Legacy], go to step 4.
[Alert I/F 1]: This system is connected to a device that outputs the ALR sentence.
[Alert I/F 2]: This system is connected to a bridge alarm system.
[Legacy]: This system is connected to the IF-2503. Set the baud rate to 4800 bps.
(See paragraph 3.8.1.)
4. Select [3 Remote Ack I/F].
5. Select [1 Ack] or [2 Buzzer Stop].
[Ack]: Acknowledge an alert and stop the buzzer.
[Buzzer Stop]: Stop the buzzer.
6. Press the
MENU ESC
key to close the main menu.