4. INSTALLING OPTIONAL EQUIPMENT
4-18
Connection
Insert each cable to the cable gland as follows.
Vinyl sheath
Clamping gland
Flat washer
Trim the armor with width of washer (5 mm).
5 mm
5 mm
Gasket
Connect each cable cores to the terminal board, referring to the interconnection diagram on
next page.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
RG12/UY
RG-12/UY
TTYCY-4
DPYCY-6
RW-9600
Connect inner conductors.
M8 screw for grounding
Clamp outer conductor of coaxial cables.
Fix wires with cable-tie.