2. WIRING
2-7
2.4
Transceiver Unit DS-620
Cables TTYCY-4S, DPYCY-4 and the transducer cable are connected to the DS-620.
Fabricate and pass them through their respective the cable clamps at the bottom.
DS-620 Transceiver unit
Note:
The transducer cable has nine twisted-pairs of signal lines (w/polarity). Be care-
ful to connect them to the correct connectors in the transceiver unit.
80
30
7
Vinyl tape
TTYCY-4S
10
80
×3
DPYCY-4
150
30
10
Conductive tape
(TR-19 L=3000, supplied)
Wrap the conductive tape around cable
two or three times, and set the taped part
in the cable clamp.
7
Transducer cable
400 (for TB6*)
250 (for TB5*)
150 (for TB4*)
100
Vinyl tape
Wrap wires of cables connected
to TB4, TB5 and TB6 with conductive
tape. Then, wrap them with vinyl tape.
×3
×3
×3
TB1
TB2
TB4
TB5
TB6
DPYCY-4.0
TTYCY-4S
Transducer cable
20
20
20
50
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1 2
IV-3.5 sq
Summary of Contents for DS-60
Page 51: ...APPENDIX 1 CALIBRATION AP 3 ...
Page 59: ...8 Mar 2010 Y NISHIYAMA D 1 ...
Page 60: ...18 Dec 2012 Y NISHIYAMA D 2 ...
Page 61: ...18 Dec 2012 Y NISHIYAMA D 3 ...
Page 62: ...D 4 30 Jun 2015 H MAKI ...
Page 63: ...D 5 30 Jun 2015 H MAKI ...
Page 64: ...1 Jul 2011 Y NISHIYAMA D 6 ...
Page 65: ...29 Mar 2011 Y NISHIYAMA D 7 ...
Page 66: ...29 Mar 2011 Y NISHIYAMA D 8 ...
Page 67: ...D 9 30 Jun 2015 H MAKI ...
Page 68: ...D 10 30 Jun 2015 H MAKI ...
Page 69: ...D 11 15 Apr 2016 H MAKI ...
Page 70: ...D 12 15 Apr 2016 H MAKI ...
Page 71: ...D 13 15 Apr 2016 H MAKI ...
Page 72: ...D 14 15 May 2015 H MAKI ...