1. INSTALLATION
1-17
8. Use the tightening handle (option) to fasten the fixing gland (6) from the inside of
the tank (2).
The distance between the bottom of the fixing gland (6) and tank must be less than
15 mm.
Transducer tank, sectional view
9. Rotate the fixing flange (4) twice horizontally to make two loops.
These loops make it easy to put the cable in the tank.
10. Use the bolt M10x25 (9) and spring washer M10 (10) to fasten the fixing flange (4)
to the tank (2).
less than 15 mm
Fixing gland
Tank
Transducer cable
M10x25 hex. bolt (9)
M10 spring washer (10)
Rotate the fixing flange (4) twice horizontally
to make two loops on the cable.