Page 20
M
M
e
e
n
n
u
u
N
N
a
a
v
v
i
i
g
g
a
a
t
t
i
i
o
o
n
n
D
D
i
i
a
a
g
g
r
r
a
a
m
m
BARCODE I/D
CHECK FILL PRESS.
PEAK VALUE
AUTO PREFILL
AUTO PREFILL
PREFILL TOLERANCE
PREFILL PRESSURE
PREFILL TIME
LEAK UNITS
PRESSURE UNITS
PRESSURE UNITS
PRESSURE UNITS
PRESSURE UNITS
A.Z. DELAY (S)
PRESSURE CORRECTION
CONTINUOUS FILL
PRESSURE CORRECTION *
GLOBAL
SETTINGS
TEST
DATA
TEST PRESSURE
TEST PRESSURE
PRESSURE TOLERANCE
PRESSURE TOLERANCE
* DUMP TEST ONLY
VENT PREFILL TIME **
LEAK AT END OF TEST
I/O FUNCTIONS
TIMER 2 TRIGGER
TEST I/D
CHECK STANDBY PRESS.
CHECK STANDBY PRESS.
OPERATION
REGULATOR 2
REGULATOR 2
LANGUAGE
VENT TIME
VENT TIME
RESET DELAY (S)
STABILISATION TIME
RESET ON PASS
TEST TIME
TEST TIME
RESET ON FAIL
CONFIGURE
TIMER 1 (S)
TEST TYPE
PREFILL TOLERANCE
ALTER PRODUCT
FILL TIME
FILL TIME
(BLOCKAGE or COARSE)
(LEAK or DUMP)
- FAIL 2
ENABLE FAIL 2
PRODUCT
DATA
PRODUCT I/D
NUMBER OF STEPS
DELAY BETWEEN STEPS
STEP 1
CONTINUE ON
}
Repeat for all steps
PREFILL TIME
ENABLE PREFILL
TIMER 2 (S)
CONFIGURE
TIMER 1 TRIGGER
COMBO 1 FUNCTION
COMBO 1 INPUT 1
COMBO 1 INPUT 2
FAIL HIGH
+ FAIL 1
LK RESOLUTION (DIGITS)
FAIL LOW
- FAIL 1
PR RESOLUTION (DIGITS)
+ FAIL 2
FILL ON FAIL
END ON FAIL
PREFILL PRESSURE
PRODUCT NUMBER
OFFSET
VOLUME
STATUS LINE
COMBO 2 FUNCTION
COMBO 2 INPUT 1
COMBO 2 INPUT 2
COMBO 3 FUNCTION
COMBO 3 INPUT 1
COMBO 3 INPUT 2
COMBO 4 FUNCTION
COMBO 4 INPUT 1
COMBO 4 INPUT 2
OUTPUTS 1-8
PNEUMATIC 1
OUTPUTS 9-16
PNEUMATIC 2
OUTPUTS 17-24
PNEUMATIC 3
OUTPUTS 25-32
PNEUMATIC 4
USER OUTPUT A
PNEUMATIC 5
USER OUTPUT B
USER OUTPUT C
USER OUTPUT D
USER OUTPUT E
USER OUTPUT F
USER OUTPUT G
USER OUTPUT H
START/RESET
VENT SENSOR
JIG SENSOR
JIG DELAY (S)
INPUTS 1-4
INPUTS 5-8
INPUTS 9-12
INPUTS 13-16
INPUTS 17-20
INPUTS 21-24
USER INPUT A
USER INPUT B
USER INPUT C
USER INPUT D
USER INPUT E
USER INPUT F
USER INPUT G
USER INPUT H
FEEDBACK A-H
FEEDBACK A-H
FEEDBACK TIMEOUT
FEEDBACK TIMEOUT
TRACK FILTER
TEST OUTPUT H
TEST OUTPUT H
TEST OUTPUT A
TEST OUTPUT A
EXTERNAL FAIL
EXTERNAL FAIL
TEST PRESSURE
PRESSURE TOLERANCE
CHECK STANDBY PRESS.
REGULATOR 2
VENT TIME
(PERMFILL)
FEEDBACK A-H
FEEDBACK TIMEOUT
TEST OUTPUT H
TEST OUTPUT A
SENSITIVITY
REGULATOR 2
VENT TIME
TEST TIME
HOLD OFF
FAIL HIGH
FAIL LOW
FEEDBACK A-H
FEEDBACK TIMEOUT
TEST OUTPUT H
TEST OUTPUT A
(RAMP)
TEST TIME
FEEDBACK A-H
FEEDBACK TIMEOUT
TEST OUTPUT H
TEST OUTPUT A
(INPUT/OUTPUT)
EXTERNAL FAIL
PRODUCT SELECTED
TEST SELECTED
** STAB PREFILL TIME FOR DUMP TEST
INPUTS
OUTPUTS
Summary of Contents for FCO770