I/O FUNCTIONS MENU
TIMER 1 (s)
TIMER 2 (s)
•
There are two general-purpose timers that may be used for jigging functions, e.g. to
operate a stamp. When triggered, the timer generates an output signal for the time
period set here. The output signal can be selected for use by the programmable
pneumatic or electrical outputs.
•
Options: 0.00 to 9.99 seconds.
TIMER 1 TRIGGER
TIMER 2 TRIGGER
•
Define the output / event / function that starts the timer.
•
Options: See the output function list on page 40.
COMBO x FUNCTION
(where x is 1, 2, 3, or 4)
•
There are four combinational outputs that may be used for jigging functions. These
apply a logical function to two signals from the Common Output Function List to give
a new output signal. The combo function block should be considered a having two
inputs and one output. The inputs to the function are chosen below. The output can be
selected for use by the programmable pneumatic or electrical outputs. The combo
function can be selected from:
o
OR
output active if either input 1 OR input 2 is active
o
AND
output active if both input 1 AND input 2 are active
o
NOR
output inactive if either input 1 OR input 2 is active
o
NAND
output inactive if both input 1 AND input 2 are active
COMBO x INPUT 1
COMBO x INPUT 2 (where x is 1, 2, 3, or 4)
•
Define the signals to input to the combo function.
•
Options: See the output function list on page 40.