SH-E514TR1 10 Gigabit Ethernet SmartPro Switch User Manual
20
Write Delay:
Enter the interval for periodic writing of the logging buffer to FLASH. This value must be between 0 and
65535 seconds. By default, this value is 300 seconds. Tick
Infinite
to disable the write delay feature.
Click
Apply
to accept the changes made for each individual section.
System Log Discriminator Settings
This window is used to view and configure the system log’s discriminator settings.
Figure 7-8 System Log Discriminator Settings
The fields that can be configured are described below:
Discriminator Name:
Enter the discriminator name here. This name can be up to 15 characters long.
Action:
Select the facility’s behavior option and the type of facility that will be associated with the selected behavior
here. Behavior options to choose from are
Drops
and
Includes
.
Severity:
Select the severity behavior option and the value of the type of information that will be logged. Behavior
options to choose from are
Drops
and
Includes
. Severity value options to choose from are
0 (Emergencies)
,
1
(Alerts)
,
2 (Critical)
,
3 (Errors)
,
4 (Warnings)
,
5 (Notifications)
,
6 (Informational)
, and
7 (Debugging)
.
Click
Apply
to accept the changes made.
Click
Delete
to remove the specified entry.
System Log Server Settings
This window is used to view and configure system log’s server settings.
Figure 7-9 System Log Server Settings
The fields that can be configured are described below:
Host IPv4 Address:
Specifies the IPv4 address of the system log server.
UDP Port:
Specifies the UDP port to which the server logs are sent. This value must be 514, or between 1024 and
65535. The default value is 514.