PSU status indicator (1)
Status
Description
flashing green
The server is switched off, but mains voltage is present
(standby mode).
green on
The server is switched on and operating properly.
flashing amber
An overload has been detected. The PSU is still running,
but failure might be imminent.
amber on
A PSU failure has been detected.
17.2.4
Acoustic indicators
PEI Beep Codes
Pre-EFI Initialization (PEI) - memory Initialization (bootblock)
# of
Beep
Description
Action
1
Memory not installed
▶
Check if the memory module is
installed.
▶
Check if the memory module is
installed correctly.
2
Recovery started
Recovery procedure is initialized by
jumper settings on the system board and
announced with two beep.
This is only an information.
4
Recovery failed
▶
Restart the recovery procedure again.
▶
If the same beep code sounds again,
replace the system board.
DXE Beep Codes
Driver Execution Environment (DXE) - main hardware Initialization (POST)
Appendix A
GX2570 M6
Upgrade and Maintenance Manual
269
Summary of Contents for PRIMERGY GX2570 M6
Page 66: ...Basic hardware procedures 66 Upgrade and Maintenance Manual GX2570 M6 ...
Page 78: ...Basic software procedures 78 Upgrade and Maintenance Manual GX2570 M6 ...
Page 154: ...Expansion cards and riser modules 154 Upgrade and Maintenance Manual GX2570 M6 ...
Page 188: ...Graphic processor GPU 188 Upgrade and Maintenance Manual GX2570 M6 ...
Page 234: ... Switching on the server on page 49 Midplane kit 234 Upgrade and Maintenance Manual GX2570 M6 ...
Page 242: ...Front panel 242 Upgrade and Maintenance Manual GX2570 M6 ...
Page 252: ...System board and components 252 Upgrade and Maintenance Manual GX2570 M6 ...
Page 274: ...Appendix A 274 Upgrade and Maintenance Manual GX2570 M6 ...
Page 281: ...AIOM adapter Card AIOM adapter Card AOM 438G AIOM P VGA Port C11 JVGA1 ...