"Removing the GPU node" on page 51
Replacing the defective CMOS battery
1
2
3
4
Figure 198: Replacing the CMOS battery
▶
Press the locking spring into direction of the arrow (1), so that the CMOS
battery jumps out of its socket.
▶
Remove the CMOS battery (2).
CAUTION
Sharp tools such as screw drivers might damage system board
components in case of slipping.
▶
If the CMOS battery cannot be ejected without the help of a tool,
it is recommended to use a tooth pick.
▶
Insert a new CMOS battery of the same type into the socket (3) and (4).
Concluding steps
▶
Dispose of the CMOS battery in accordance with local regulations
concerning special waste.
▶
"Installing the GPU node" on page 53
▶
▶
"Connecting the power cord" on page 48
▶
"Switching on the server" on page 49
System board and components
GX2570 M6
Upgrade and Maintenance Manual
245
Summary of Contents for PRIMERGY GX2570 M6
Page 66: ...Basic hardware procedures 66 Upgrade and Maintenance Manual GX2570 M6 ...
Page 78: ...Basic software procedures 78 Upgrade and Maintenance Manual GX2570 M6 ...
Page 154: ...Expansion cards and riser modules 154 Upgrade and Maintenance Manual GX2570 M6 ...
Page 188: ...Graphic processor GPU 188 Upgrade and Maintenance Manual GX2570 M6 ...
Page 234: ... Switching on the server on page 49 Midplane kit 234 Upgrade and Maintenance Manual GX2570 M6 ...
Page 242: ...Front panel 242 Upgrade and Maintenance Manual GX2570 M6 ...
Page 252: ...System board and components 252 Upgrade and Maintenance Manual GX2570 M6 ...
Page 274: ...Appendix A 274 Upgrade and Maintenance Manual GX2570 M6 ...
Page 281: ...AIOM adapter Card AIOM adapter Card AOM 438G AIOM P VGA Port C11 JVGA1 ...