Concluding steps
▶
"Installing the cross bar" on page 65
▶
"Installing the air duct" on page 63
▶
"Installing the CPU node" on page 50
▶
"Connecting the power cord" on page 48
.
▶
"Switching on the server" on page 49
.
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed
.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the
Exit
menu.
●
Select
Commit settings and Exit
.
●
Verify that the Global Error indicator stops flashing.
13.3
Replacing the GPU or LC kit
Field Replaceable Unit
(FRU)
Hardware: 30 minutes
Tools:
– Phillips PH2 / (+) No. 2 screw driver (for GPU node)
– Torx T15 screw driver
Liquid cooling (LC)
206
Upgrade and Maintenance Manual
GX2570 M6
Summary of Contents for PRIMERGY GX2570 M6
Page 66: ...Basic hardware procedures 66 Upgrade and Maintenance Manual GX2570 M6 ...
Page 78: ...Basic software procedures 78 Upgrade and Maintenance Manual GX2570 M6 ...
Page 154: ...Expansion cards and riser modules 154 Upgrade and Maintenance Manual GX2570 M6 ...
Page 188: ...Graphic processor GPU 188 Upgrade and Maintenance Manual GX2570 M6 ...
Page 234: ... Switching on the server on page 49 Midplane kit 234 Upgrade and Maintenance Manual GX2570 M6 ...
Page 242: ...Front panel 242 Upgrade and Maintenance Manual GX2570 M6 ...
Page 252: ...System board and components 252 Upgrade and Maintenance Manual GX2570 M6 ...
Page 274: ...Appendix A 274 Upgrade and Maintenance Manual GX2570 M6 ...
Page 281: ...AIOM adapter Card AIOM adapter Card AOM 438G AIOM P VGA Port C11 JVGA1 ...