8
C120-E093-04EN
CHAPTER 2 Specifications and Installation Overview of the Main Unit
•
19-inch rack space outlet box (in Japan)
Figure 2.3
shows the 19-inch rack space outlet box (in Japan).
Figure 2.3 Outlets for the 19-inch Rack Spaces (In Japan)
Table 2.3
specifies the outlet specifications (in Japan).
Note1: Power supply system #0 and #1 become separate when installing Dual power feed
option.
Note2: For the 200V (3.5) connectors, there are six connectors, and four connectors are available
for users. Two of the connectors are used for the File Unit installed in the basic package.
Note3: Total value of two outlets.
l
Do not use the 100-VAC (0.65-A) outlet marked MAINTE, which is the top plug of the three
100-VAC plugs with three parallel pins. This outlet is required for maintenance by a certified
service engineer.
Table 2.3 Outlet Specifications of 19-inch Rack (In Japan)
Power Supply
System #
(Note1)
Voltage
(Max. current)
# of
pieces
Connector type
Main purpose of use
#0
200 V (3.5 A)
(Note2)
3
IEC320 Outlet type
Expansion File Unit
100 V (0.35 A)
(Note3)
2
3 Parallel pins
System Control LAN HUB/
Console Connection Unit
100 V (0.65 A)
1
3 Parallel pins
(with switch)
For certified service
engineer
#1
200 V (3.5 A)
(Note2)
3
IEC320 Outlet type
Expansion File Unit
Summary of Contents for PRIMEPOWER 800
Page 1: ...Edition December 2001 PRIMEPOWER1000 800 ...
Page 5: ...PRIMEPOWER 1000 800 User s Manual C120 E093 04EN ...
Page 6: ......
Page 10: ......
Page 20: ......
Page 54: ...26 C120 E093 04EN CHAPTER 4 Hardware Overview Figure 4 4 System Board ...
Page 92: ......
Page 96: ......
Page 114: ......
Page 116: ......
Page 130: ......
Page 134: ......
Page 140: ......
Page 142: ......
Page 144: ......