[ERR.]
xos
RAS
0021
-
internal
information
GPR,
SP
register
error
detected.
esr=DATA1
ERR0STATUS=DATA2
Meaning
A
parity
error
was
detected
in
GPR
or
Stackpointer.
DATA1
:
ESR
register
value
DATA2
:
Error
status
register
value
Action
Collect
investigation
data
according
to
"
,"
and
then
contact
Fujitsu
Support
with
the
collected
data
together
with
the
output
message.
[ERR.]
xos
RAS
0022
-
internal
information
FP&SIMD,
vector,
predicate
register
error
detected.
esr=DATA1
ERR0STATUS=DATA2
Meaning
A
parity
error
was
detected
in
the
FP&SIMD
register.
DATA1
:
ESR
register
value
DATA2
:
Error
status
register
value
Action
Collect
investigation
data
according
to
"
,"
and
then
contact
Fujitsu
Support
with
the
collected
data
together
with
the
output
message.
[ERR.]
xos
RAS
0023
-
internal
information
Invalid
error
code
or
type
detected
when
SError
occurred.
esr=DATA1
ERR0STATUS=DATA2
Meaning
SError
occurred.
The
error
code
or
error
type
is
invalid.
DATA1
:
ESR
register
value
DATA2
:
Error
status
register
value
Action
Collect
investigation
data
according
to
"
,"
and
then
contact
Fujitsu
Support
with
the
collected
data
together
with
the
output
message.
[ERR.]
xos
RAS
0024
-
internal
information
MARKED_UE
detected.
esr=DATA1
ERR0STATUS=DATA2
Meaning
Error-marked
data
was
used.
DATA1
:
ESR
register
value
DATA2
:
Error
status
register
value
Action
Collect
investigation
data
according
to
"
,"
and
then
contact
Fujitsu
Support
with
the
collected
data
together
with
the
output
message.
[ERR.]
xos
RAS
0025
-
internal
information
Uncorrectable
Address
Error(Load,
Instruction
access)
detected.
esr=DATA1
ERR0STATUS=DATA2
Meaning
An
error
due
to
incorrect
memory
access
(Load,
Instruction
access)
was
detected.
DATA1
:
ESR
register
value
DATA2
:
Error
status
register
value
Action
Appendix
B
CPU-MEM-RAS
Driver
Messages
C120-0089-03EN
76
Summary of Contents for PRIMEHPC FX1000