C141-E054-02EN
1 - 37
•
The drive responds with LS_RJT (03h,
0Bh) when (this bit) = 0.
•
For ACC, the drive responds with 1b.
(5) Buffer-to-buffer Receive Size [PL:W02/B2-3]
•
The drive responds with LS_RJT (03h,
07h) when 256 = < (this field) = < 2112
not a multiple of 4.
•
The drive responds with the value of the
receive data field size of class 3 parameter
of PLOG1 by ACC.
(6) Total Concurrent Sequence [PL:W03/B1]
•
The drive does not check this field.
•
For ACC, the drive responds with FFh.
(7) Relative Offset by category [PL:W03/B2-3]
•
The drive does not check this field.
•
For ACC, the drive responds with 0002h.
(This indicates that Information Category is
Solicited data when bit 1 = 1.)
(8) Point-to-point E_D_TOV value [PL:W04/B0-3]
This field is significant for point-to-point
connection and invalid for loop connection.
•
The drive does not check this field.