Chapter 3 - Setup and Installation
Multi-Port Mirrored Single Host-Single Connection Configuration
76
Disk I/O Card
2
Re-install the Disk I/O card. Repeat step 1 for the second Disk I/O card.
3
Locate the switches on the SES Controller card and set them as indicated in
the illustration on the following page. Refer to “SES Controller Card Switch
Setting Overview” on page 52 for the other available settings.
Disk I/O Card Jumper Settings for the imageRAID IRF-2Sxx-xx/IRF-2Dxx-xx Enclosures
JUMPER
INSTALLED BOTH PINS
INSTALLED ONE PIN (OFFSET)
JP1
imageRAID Controllers Only
* Non-imageRAID Controllers
JP2
imageRAID Controllers Only
* Non-imageRAID Controllers
JP3
Split Bus Mode
JBOD Enclosures Only
* Single Bus Mode
RAID Enclosures and Daisy
Chain JBOD Enclosures
JP4
1 Gb/sec Bus Speed Mode
* 2 Gb/sec Bus Speed Mode
* indicates default setting
P1
DISK I/O
P2
OK
OK
2G
Fibre Disk IO
LRC
P/N 08-9-96
318001
A/W Re
v-1
INST
ALL JUMPE
RS 1 & 2
FOR HARD
WARE
FAILURE DETEC
T
ADD JUMPE
R FOR
1G OPERA
TION
JP1
JP4
JP3
JP2
ADD JUMPE
R FOR
SPLIT B
US MODE
FC-AL Loop Port
Loop Status LED
2 Gb/1 Gb Mode LED
Jumper JP3 must be offset
or installed on one pin only.
This enables Single Bus mode.
Jumper JP4 must be set
to one pin only for 2Gb mode.
Position it on both pins for
1Gb mode.
Jumpers JP1 and JP2
must be installed on
both pins .
imageRAID.book Page 76 Tuesday, September 23, 2003 4:08 PM
Summary of Contents for IRF-1D series
Page 2: ...imageRAID book Page 2 Tuesday September 23 2003 4 08 PM ...
Page 8: ...Table of Contents iv imageRAID book Page iv Tuesday September 23 2003 4 08 PM ...
Page 180: ...Index 168 imageRAID book Page 168 Tuesday September 23 2003 4 08 PM ...
Page 181: ...imageRAID book Page 7 Tuesday September 23 2003 4 08 PM ...