Chapter 3 - Setup and Installation
Multi-Port Mirrored Single Host-Single Connection Configuration
78
Multi-Port Mirrored Single Host-Single Connection Cabling Diagram
7
If you wish to add additional enclosure(s), follow the instructions below.
Otherwise skip to step 13. The example depicts one extra enclosure being
added, however, you may wish to add more enclosures up to the allowable
limit of 96 drives.
8
Set the jumper (JP4) on the Disk I/O card installed in the expansion enclosure.
Loosen the two captive fastener screws on the Disk I/O card and pull it from
the daisy-chain enclosure using the fastener screws. Locate the jumper JP4
and position it for the desired speed setting, (installed on one pin only for 2
Gb mode and on both pins for 1 Gb mode).
Disk I/O Card Jumper Settings for the IRF-JBOD Enclosures
JUMPER
INSTALLED BOTH PINS
INSTALLED ONE PIN (OFFSET)
JP1
imageRAID Controllers Only
* Non-imageRAID Controllers
JP2
imageRAID Controllers Only
* Non-imageRAID Controllers
JP3
Split Bus Mode
JBOD Enclosures Only
* Single Bus Mode
RAID Enclosures and Daisy
Chain JBOD Enclosures
JP4
1 Gb/sec Bus Speed Mode
* 2 Gb/sec Bus Speed Mode
* indicates default setting
FC HBA 1
SES
Host Computer
imageRAID IRF-2Sxx-xx/IRF-2Dxx-xx
H0
H1
H0
H1
RAID Controller
RAID Controller
Power
Supply
Power
Supply
Cooling
Fans
DISK I/O
P1
RS-232
P2
DISK I/O
P1
P2
Connect to H0
imageRAID.book Page 78 Tuesday, September 23, 2003 4:08 PM
Summary of Contents for IRF-1D series
Page 2: ...imageRAID book Page 2 Tuesday September 23 2003 4 08 PM ...
Page 8: ...Table of Contents iv imageRAID book Page iv Tuesday September 23 2003 4 08 PM ...
Page 180: ...Index 168 imageRAID book Page 168 Tuesday September 23 2003 4 08 PM ...
Page 181: ...imageRAID book Page 7 Tuesday September 23 2003 4 08 PM ...