Chapter 3 - Setup and Installation
Stand-Alone Dual Port Dual Host Single Connection Configuration
67
6
Connect the Fibre Channel data cable(s).
a
Connect a cable from the first host (Node A) HBA FC port to the “H0”
connector on the left Host I/O card.
b
Connect a cable from the second host (Node B) HBA FC port to the “H1”
connector on the right Host I/O card.
Stand-Alone Dual Port Dual Host Single Connection Cabling Diagram
7
If you wish to add additional enclosure(s), follow the instructions below.
Otherwise skip to step 13. The example depicts one extra enclosure being
added, however, you may wish to add more enclosures up to the allowable
limit of 96 drives.
8
Set the jumper (JP4) on the Disk I/O card installed in the expansion enclosure.
Loosen the two captive fastener screws on the Disk I/O card and pull it from
the daisy-chain enclosure using the fastener screws. Locate the jumper JP4
and position it for the desired speed setting, (installed on one pin only for 2
Gb mode and on both pins for 1 Gb mode).
SES
Host Computer Node B
H0
H1
H0
H1
RAID Controller
Power
Supply
Power
Supply
Cooling
Fans
DISK I/O
Host Computer Node A
P1
RS-232
P2
DISK I/O
P1
P2
FC HBA 1
FC HBA 1
Connect to H1
Connect to H0
imageRAID IRF-1Sxx-xx/IRF-1Dxx-xx
imageRAID.book Page 67 Tuesday, September 23, 2003 4:08 PM
Summary of Contents for IRF-1D series
Page 2: ...imageRAID book Page 2 Tuesday September 23 2003 4 08 PM ...
Page 8: ...Table of Contents iv imageRAID book Page iv Tuesday September 23 2003 4 08 PM ...
Page 180: ...Index 168 imageRAID book Page 168 Tuesday September 23 2003 4 08 PM ...
Page 181: ...imageRAID book Page 7 Tuesday September 23 2003 4 08 PM ...