Chapter 3 - Setup and Installation
Stand-Alone Dual Port Single Host Dual Connection Configuration
60
Stand-Alone Dual Port Single Host Dual Connection Configuration
1
Set the jumper (JP4) on the Disk I/O card to configure the bus speed mode.
Loosen the two captive fastener screws on the Disk I/O card and pull it from
the enclosure using the fastener screws. Locate the jumper JP4 and position it
for the desired speed setting, (installed on one pin only for 2 Gb mode and
on both pins for 1 Gb mode).
Disk I/O Card
2
Re-install the Disk I/O card. Repeat this step for the second Disk I/O card.
Disk I/O Card Jumper Settings for the imageRAID IRF-1Sxx-xx/IRF-1Dxx-xx Enclosures
JUMPER
INSTALLED BOTH PINS
INSTALLED ONE PIN (OFFSET)
JP1
imageRAID Controllers Only
* Non-imageRAID Controllers
JP2
imageRAID Controllers Only
* Non-imageRAID Controllers
JP3
Split Bus Mode
JBOD Enclosures Only
* Single Bus Mode
RAID Enclosures and Daisy
Chain JBOD Enclosures
JP4
1 Gb/sec Bus Speed Mode
* 2 Gb/sec Bus Speed Mode
* indicates default setting
P1
DISK I/O
P2
OK
OK
2G
Fibre
Disk IO
LRC
P/N 0
8-9-9
6318
001
A/W
Rev-1
INSTA
LL JU
MPE
RS 1
& 2
FOR
HAR
DWA
RE
FAILU
RE D
ETEC
T
ADD
JUM
PER
FOR
1G O
PER
ATIO
N
JP1
JP4
JP3
JP2
ADD
JUM
PER
FOR
SPLIT
BUS
MOD
E
FC-AL Loop Port
Loop Status LED
2 Gb/1 Gb Mode LED
Jumper JP3 must be offset
or installed on one pin only.
This enables Single Bus mode.
Jumper JP4 must be set
to one pin only for 2Gb mode.
Position it on both pins for
1Gb mode.
Jumpers JP1 and JP2
must be installed on
both pins .
imageRAID.book Page 60 Tuesday, September 23, 2003 4:08 PM
Summary of Contents for IRF-1D series
Page 2: ...imageRAID book Page 2 Tuesday September 23 2003 4 08 PM ...
Page 8: ...Table of Contents iv imageRAID book Page iv Tuesday September 23 2003 4 08 PM ...
Page 180: ...Index 168 imageRAID book Page 168 Tuesday September 23 2003 4 08 PM ...
Page 181: ...imageRAID book Page 7 Tuesday September 23 2003 4 08 PM ...