Chapter 3 - Setup and Installation
Multi-Port Mirrored SAN Attach-Single Switch Configuration
100
b
Connect another data cable from the “P2” connector on the lower Disk
I/O card installed in the primary RAID enclosure to the “P1” connector
on the upper Disk I/O card in the daisy-chain enclosure.
Multi-Port Mirrored SAN Attach-Single Switch Connection Cabling Diagram (Daisy-Chain)
CAUTION:
When using dual loop topologies, you will be required to install
and use volume management software.
12
Repeat steps 8 through 11 for each additional daisy-chained enclosure.
13
Power on your system, refer to “Powering On the Storage System” on
This completes the setup and cabling of this configuration.
SES
H0
H1
H0
H1
RAID Controller
RAID Controller
Power
Supply
Power
Supply
Cooling
Fans
DISK I/O
P1
RS-232
P2
DISK I/O
P1
P2
SES
Power
Supply
Power
Supply
Cooling
Fans
DISK I/O
P1
RS-232
P2
DISK I/O
P1
P2
Accesses Loop 0
Drive Slots 1-12
Accesses Loop 1
Drive Slots 1-12
Connect to P1
Connect to P1
FC HBA
FC HBA
Host Computer Node B
Switch/Hub
Connect H0
Connect H1
Host Computer Node A
imageRAID IRF-2Sxx-xx/IRF-2Dxx-xx
imageRAID IRF-JBOD
imageRAID.book Page 100 Tuesday, September 23, 2003 4:08 PM
Summary of Contents for IRF-1D series
Page 2: ...imageRAID book Page 2 Tuesday September 23 2003 4 08 PM ...
Page 8: ...Table of Contents iv imageRAID book Page iv Tuesday September 23 2003 4 08 PM ...
Page 180: ...Index 168 imageRAID book Page 168 Tuesday September 23 2003 4 08 PM ...
Page 181: ...imageRAID book Page 7 Tuesday September 23 2003 4 08 PM ...