Appendix B - Port Information
SES Controller Card RS-232 Service Port
158
The SFP transceiver is a Class 1 Laser safety compliant device and conforms to
Class 1 eye safety standards.
CAUTION:
Do not look into the laser light beam for any extended period of time.
Dust covers are provided to protect the transceivers’ optics. We highly
recommend using the dust covers provided.
SES Controller Card RS-232 Service Port
Located below the Disk I/O cards at the rear of the enclosure is the SES
Controller card with a RS-232 Service port. It provides the serial interface to the
SES processors allowing for firmware uploads, maintenance and monitoring.
Below is the pin signals for this port. A null-modem cable is required for
connectivity.
SES Controller Card RS-232 Service Port Pin Signals
1
1
NC
2
Rx
3
Tx
4
NC
5
Gnd
6
NC
7
NC
8
NC
9
NC
Pin Number Signal Name
2
3
4
5
6
7
8
9
imageRAID.book Page 158 Tuesday, September 23, 2003 4:08 PM