Table 4.4 Error codes
Error Code
Description
User Action
80
Barcode Reader Error, cannot initialize BCR
Retry operation; after several occurrences contact
technical support
81
Barcode Reader Error, no response from BCR
Retry operation; after several occurrences contact
technical support
82
EEPROM Error, no response from EEPROM (located
on robotic controller)
Retry operation; after several occurrences contact
technical support
83
Robotic controller generic problem
Reset the unit and retry operation. After several
occurrences contact technical support
84
Setting of gripper motor parameters failed
Reset the unit and retry operation. After several
occurrences contact technical support
85
Setting of slider motor parameters failed
Reset the unit and retry operation. After several
occurrences contact technical support
86
Setting of elevator motor parameters failed
Reset the unit and retry operation. After several
occurrences contact technical support
87
Setting of rotation motor parameters failed
Reset the unit and retry operation. After several
occurrences contact technical support
88
Setting of sled motor parameters failed
Reset the unit and retry operation. After several
occurrences contact technical support
89
Gripper blocked
Run 'Library Health Check', after several
occurrences contact technical support
8A
Slider blocked
Run 'Library Health Check', after several
occurrences contact technical support
8B
Elevator blocked
Run 'Library Health Check', after several
occurrences contact technical support
8C
Rotation blocked
Run 'Library Health Check', after several
occurrences contact technical support
8D
Sled blocked
Run 'Library Health Check', after several
occurrences contact technical support
8E
Cannot find gripper block within the expected
range
Run 'Library Health Check', after several
occurrences contact technical support
8F
Cannot find slider block within the expected range
Run 'Library Health Check', after several
occurrences contact technical support
90
Cannot find elevator block within the expected
range
Run 'Library Health Check', after several
occurrences contact technical support
91
Cannot find rotation block within the expected
range
Run 'Library Health Check', after several
occurrences contact technical support
92
Cannot find sled block within the expected range
Run 'Library Health Check', after several
occurrences contact technical support
93
Gripper outside range, Gripper has reached a
position beyond the expected range
Run 'Library Health Check', after several
occurrences contact technical support
94
Slider outside range, Slider has reached a position
beyond the expected range
Run 'Library Health Check', after several
occurrences contact technical support
95
Elevator outside range, Elevator has reached a
position beyond the expected range
Run 'Library Health Check', after several
occurrences contact technical support