Chapter 2 Installing the Tape Library
2.5 Rack Mounting the Library
FUJITSU Storage ETERNUS LT40 S2/LT60 S2 LTO Library Installing, Starting Up and Maintaining
Copyright 2018 FUJITSU LIMITED
P3AM-5392-07ENZ0
30
6
Then fasten the rail on the rear side with two screws with centering washers as shown
below.
Figure 2.11 Mounted right sliding rail (rear side)
7
Mount the left rail in the same way:
•
In PRIMECENTER racks, put the positioning tappet of the left rail into the appropriate hole of the
support bracket which you have mounted on the left rear rack post.
•
Compress the spring mounted rail to its length, putting the preloaded screw head in the lower front
lug of the rail from behind into the appropriate hole of the left front rack post.
•
Screw on the upper lug of the front rail end to the left front rack post with one screw with centering
washer.
•
Screw on the rear rail end to support bracket with two screws with centering washers as shown
below.
Figure 2.12 Mounted left sliding rail (rear side)
CAUTION
The library weighs 16.5 kg (ETERNUS LT40
S2
) / 27 kg (ETERNUS LT60
S2
)
(without media). Most of the weight is toward the back of the library.