Chapter 3 Remote Panel Operation
3.12 Operating the Library
FUJITSU Storage ETERNUS LT270 S2 Tape Library User’s Guide -Panel Operation-
Copyright 2020 FUJITSU LIMITED
P3AM-6932-06ENZ0
140
3.12.3
Inserting/ejecting a Cleaning Cartridge
This section explains how to insert and eject a cleaning cartridge.
■
Inserting a cleaning cartridge
A cleaning cartridge is inserted into the cleaning cell.
•
A cleaning cartridge can be used only a limited number of times. If a cleaning cartridge in the cleaning
cell has reached its use limit, the cleaning cartridge can no longer be used and the Exchange Cleaning
Tape icon lights in the icon area of the operator panel. If this icon is lit, eject the cleaning cartridge, which
is now unusable, and replace it with a new cleaning cartridge.
•
If loading or ejection is attempted while the backup software is accessing the library, a message is
displayed stating that the library is busy. Retry loading or ejection when the library is no longer busy.
•
The cleaning cell is divided into two areas. One area is exclusively used for the lower robot; the other area
exclusively used for the upper robot. Always insert at least one cleaning cartridge into each of the upper
and lower areas.
•
This operation can be performed only if there is an available cleaning cell.
•
If a cleaning cartridge that cannot be inserted is detected, a media error message appears in the
operation result window. Reference the CAS Map information and check the cleaning cartridge status.