Chapter 3 Remote Panel Operation
3.12 Operating the Library
FUJITSU Storage ETERNUS LT270 S2 Tape Library User’s Guide -Panel Operation-
Copyright 2020 FUJITSU LIMITED
P3AM-6932-06ENZ0
138
3
A confirmation window is displayed.
Select the [OK] button if it is OK to proceed.
End of procedure
3.12.2
Cleaning the Drive Manually
The library has a special cell to store a cleaning cartridge in each drive. This cleaning cartridge can be used to
clean the drive manually.
This section explains how to manually clean drives.
Procedure
1
Click the [Clean] button displayed under [Operation] to display the following window.
Figure 3.50 Clean menu window
•
Cleaning cannot be carried out if the cleaning cell of the drive to be cleaned contains no cleaning
cartridge, the maximum usage count of all contained cleaning cartridges has been reached, or all of
them are in error. In these cases, insert a new cleaning cartridge or replace failed cartridges from the
operator panel (refer to
"2.13 Inserting and Ejecting Cleaning Cartridges" (page 60)
•
The drive is offline while cleaning. The drive goes online automatically after cleaning is completed.