(6)
Check the test transmission completion message and click the [Done] button.
The screen display returns to the [Network] screen.
2
Check the result of the test transmission.
Check that the SNMP Trap is notified to the monitoring server.
For details on the messages for test transmission, refer to "Message List".
If the SNMP Manager cannot receive an SNMP test trap, check that the network has no trouble, and the
settings for the ETERNUS DX Disk storage system are correct.
•
Is the LAN between the monitoring server and ETERNUS DX Disk storage system connected correctly?
Execute the "ping" command from the monitoring server, and confirm the reply from the ETERNUS DX
Disk storage system.
When "ICMP" is disabled by the firewall settings for ETERNUS Web GUI, the "ping" command cannot
be used for confirmation. Enable "ICMP" before executing the "ping" command.
•
Is the monitoring software set correctly to monitor the ETERNUS DX Disk storage system?
•
Are the SNMP environment settings and the transmission destination for the SNMP Trap set correctly
on the ETERNUS DX Disk storage system?
6.6.2
Send Test Mail
Perform the email transmission test to check that the email can be sent from the ETERNUS DX Disk storage
system to the specified email address.
The procedure to send test mail is as follows:
1
On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
2
In [Category], click [Network].
The [Network] screen appears.
3
In [Action], click [Setup E-Mail Notification].
The [Setup E-Mail Notification] screen appears.
Chapter 6 Monitoring Settings
6.6 Transmission Test Execution
119
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
P3AM-7652-02ENZ0