1-2. Custom code setting for wireless remote controller
¢
Custom code setting for wireless remote controller
To interconnect the air conditioner and the wireless remote controller, assignment of the custom
code for the wireless remote controller is required.
NOTE:
Air conditioner cannot receive a signal if the air conditioner has not been set for the custom
code.
When 2 or more air conditioners are installed in a room, and the remote controller is operating an air
conditioner other than the one you wish to set, change the custom code of the remote controller to
operate only the air conditioner you wish to set. (4 selections possible.)
Confirm the setting of the remote controller custom code and the function setting. If these do not
match, the remote controller cannot be used to operate for the air conditioner.
1. Press the
/
(START/STOP) button until the indicators on the re-
mote controller turn off.
2. Press the MODE button for at least 5 seconds to display the current
custom code. (Initially set to .)
3. Press the TEMP./SELECT ( ) ( ) buttons to change the custom
code between → → → . Match the code on the display to the
air conditioner custom code. (Initially set to .)
4. Press the MODE button again to return to the original display. The
custom code will be changed.
NOTES:
• If no button is pressed within 30 seconds after the custom code is displayed, the system returns
to the original display. In this case, start again from step 1.
• The air conditioner custom code is set to prior to shipment. To change the custom code, con-
tact your retailer.
• If you do not know the assigned code for the air conditioner, try each of the custom code ( →
→ → ) until you find the code which operates the air conditioner.
1-2. Custom code setting for wireless remote controller
- (05-10) -
1. Function settings
FIELD
WORKING
FIELD
WORKING
Summary of Contents for AOUH18LPAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 10 12 SR_CH01_AS051EF_02 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 07 04 SR_CH02_AS051EF_01 ...
Page 33: ...3 TROUBLESHOOTING 2021 08 04 SR_CH03_AS051EF_01 ...
Page 36: ......
Page 95: ...4 CONTROL AND FUNCTIONS 2021 08 04 SR_CH04_AS051EF_01 ...
Page 129: ...5 FILED WORKING 2021 08 04 SR_CH05_AS051EF_01 ...