10) Switching functions for external output terminal
Functions of the external output terminal can be switched. For details, refer to “External input and
output”.
Function number
Setting value
Setting description
Factory setting
60
00
Operation status
♦
01—04
Cooling thermostat On
05
Heating operation
06
Operation/Stop
07—08
Cooling thermostat On
09
Error status
10
Indoor unit fan operation status
11
External heater
11) Control switching of external heaters
Sets the control method for external heater to be used.
For details, refer to “External heater output” in
Chapter 2-4. "Details of function"
Function
number
Setting value
Setting description
Factory
setting
61
00
Auxiliary heater control 1
♦
01
Auxiliary heater control 2
02
Heat pump prohibition control
03
Auxiliary heater control by outdoor temperature 1
04
Auxiliary heater control by outdoor temperature 2
05
Auxiliary heater control by outdoor temperature 3
06
Auxiliary heat pump control
07
Auxiliary heat pump control by outdoor temperature 1
08
Auxiliary heat pump control by outdoor temperature 2
09
Auxiliary heat pump control by outdoor temperature 3
12) Operating temperature switching of external heaters
Sets the temperature conditions when the external heater is ON.
For details, refer to “External heater output” in
Chapter 2-4. "Details of function"
Function
number
Setting value
Setting description
Factory
setting
Heater: On
Heater: Off
62
00
-5.4 °F (-3 °C)
-1.8 °F (-1 °C)
♦
01
-3.6 °F (-2 °C)
-1.8 °F (-1 °C)
02
-3.6 °F (-2 °C)
-1.8 °F (-1 °C)
03
-5.4 °F (-3 °C)
-1.8 °F (-1 °C)
04
-7.2 °F (-4 °C)
-1.8 °F (-1 °C)
05
-9.0 °F (-5 °C)
-1.8 °F (-1 °C)
1-1. Function settings by using remote controller
- (05-7) -
1. Function settings
FIELD
WORKING
FIELD
WORKING
Summary of Contents for AOUH18LPAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 10 12 SR_CH01_AS051EF_02 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 07 04 SR_CH02_AS051EF_01 ...
Page 33: ...3 TROUBLESHOOTING 2021 08 04 SR_CH03_AS051EF_01 ...
Page 36: ......
Page 95: ...4 CONTROL AND FUNCTIONS 2021 08 04 SR_CH04_AS051EF_01 ...
Page 129: ...5 FILED WORKING 2021 08 04 SR_CH05_AS051EF_01 ...