![Fujitsu AOUH18LPAS1 Service Manual Download Page 109](http://html.mh-extra.com/html/fujitsu/aouh18lpas1/aouh18lpas1_service-manual_2344158109.webp)
Model: AOUH24LPAS1
Fan speed is defined by outdoor temperature and rotation number of compressor.
•
Outside air temperature zone selection
Outside air
temperature rises
Z zone
Y zone
F zone
G zone
Outside air
temperature drops
H zone
53.6°F
(
12
°C)
35.6°F
(
2
°C)
50.0
°F
(
10
°C)
32.0
°F
(
0
°C)
17.6°F
(
-8
°C)
14.0°F
(
-10
°C)
69.8°F
(
21
°C)
66.2
°F
(
19
°C)
Unit: rpm
Fan step
Cooling
Heating
Dry
Cooling or dry at low outdoor temp.
Y zone
Y zone
Z zone
F zone
G zone
H zone
S-HIGH2
—
1,100
—
—
—
—
—
S-HIGH1
1,050
1,100
—
—
—
—
—
HIGH
1,050
1,100
—
—
—
—
—
10
—
1,100
—
—
—
—
—
9
920
1,100
1,050
630
320
270
270
8
840
1,050
840
630
270
250
250
7
750
920
750
320
270
230
230
6
690
710
690
320
270
230
230
5
560
620
560
320
270
230
230
4
440
560
440
320
270
230
230
3
440
500
440
320
270
230
230
2
440
440
440
320
270
230
230
1
440
440
440
320
270
230
230
NOTE:
After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor rotation number.
Fan speed after defrost control: 1,100 rpm
3-2. Outdoor fan control
- (04-13) -
3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AOUH18LPAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 10 12 SR_CH01_AS051EF_02 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 07 04 SR_CH02_AS051EF_01 ...
Page 33: ...3 TROUBLESHOOTING 2021 08 04 SR_CH03_AS051EF_01 ...
Page 36: ......
Page 95: ...4 CONTROL AND FUNCTIONS 2021 08 04 SR_CH04_AS051EF_01 ...
Page 129: ...5 FILED WORKING 2021 08 04 SR_CH05_AS051EF_01 ...