1-5. Limitation of compressor rotation number by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
•
Cooling/Dry mode
F zone
E zone
D zone
C zone
B zone
A zone
14.0°F
(-10°C)
32.0°F
(0°C)
50.0°F
(10°C)
66.2°F
(19°C)
100.4°F
(38°C)
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOUH18LPAS1
AOUH24LPAS1
A zone
33 rps
B zone
33 rps
C zone
33 rps
D zone
25 rps
E zone
10 rps
F zone
20 rps
•
Heating mode
F zone
E zone
D zone
C zone
B zone
A zone
66.2°F
(19°C)
32.0°F
(0°C)
5.0°F
(-15°C)
-13.0°F
(-25°C)
41.0°F
(5°C)
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOUH18LPAS1
AOUH24LPAS1
A zone
30 rps
B zone
30 rps
C zone
30 rps
D zone
13 rps
E zone
10 rps
F zone
10 rps