
2-7. E: 26. Address setting error in wired remote controller
(Indoor unit)
Indicator
Indoor unit
Operation indicator
2 time flash
Timer indicator
6 time flash
Economy indicator
Continuous flash
Error code
E: 26
outdoor unit
Refer to “Error code table (Outdoor unit: for 34 model
only)” on page 1
Detective actuator
Wired remote controller (2-wire)
•
When the address number set by auto setting and
manual setting are mixed in one remote controller
group
•
When the duplicated address number exists in one
remote controller group
Indoor unit controller PCB
Forecast of cause
Wrong wiring of remote controller group
Wrong remote controller address setting
Indoor unit main PCB failure
Remote controller failure
Check point 1. Wire installation
•
Check the wire connection in the remote controller group (For installation method, refer to in-
stallation manual)
-> If there is an abnormal condition, correct it by refer to the installation manual or the “DESIGN
& TECHNICAL MANUAL”.
↓
Check point 2. Wrong remote controller group setting
•
The given address number by auto setting (00) and the manual set number (except 00) are not
existing in one remote controller group.
•
The remote controller address setting by UI is not existing same address.
•
The duplicate address number is not existing in one remote controller group.
↓
Check point 3. Check indoor unit main PCB
•
Check if main PCB is damaged.
•
Change main PCB and check the error after setting remote controller address.
↓
End
2-7. E: 26. Address setting error in wired remote controller (Indoor unit)
- (03-20) -
2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for AOTG30KMTC
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2019 06 27 SR_CH01_AS004EF_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 05 12 SR_CH02_AS004EF_05 ...
Page 35: ...3 TROUBLESHOOTING 2020 05 08 SR_CH03_AS004EF_02 ...
Page 38: ......
Page 128: ...6 2 Outdoor unit 03 90 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 129: ...4 CONTROL AND FUNCTIONS 2020 05 08 SR_CH04_AS004EF_02 ...
Page 132: ......
Page 163: ...5 FILED WORKING 2019 07 24 SR_CH05_AS004EF_01 ...