Error contents
POWER/
MODE
ERROR
PUMP
DOWN
LOW NOISE
PEAK CUT
L1
L2
L3
L4
L5
L6
E: 95. Compressor motor control error
(Outdoor unit)
■
2
●
■
9
■
5
○
○
○
●
E: 97. Outdoor unit fan motor error
(Outdoor unit)
■
2
●
■
9
■
7
○
○
●
●
E: 99. 4-way valve error (Outdoor unit)
■
2
●
■
9
■
9
○
○
○
●
E: A1. Discharge temperature error
(Outdoor unit)
■
2
●
■
10
■
1
○
○
○
●
E: A3. Compressor temperature error
(Outdoor unit)
■
2
●
■
10
■
3
○
○
○
●
E: A5. Low pressure error (Outdoor
unit)
■
2
●
■
10
■
5
○
○
○
●
●
: Light on
○
: Light off
■
(n) : n Times blinking
1-2. Error code table (Outdoor unit: for 34 model only)
- (03-4) -
1. Error code
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for AOTG30KMTC
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2019 06 27 SR_CH01_AS004EF_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 05 12 SR_CH02_AS004EF_05 ...
Page 35: ...3 TROUBLESHOOTING 2020 05 08 SR_CH03_AS004EF_02 ...
Page 38: ......
Page 128: ...6 2 Outdoor unit 03 90 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 129: ...4 CONTROL AND FUNCTIONS 2020 05 08 SR_CH04_AS004EF_02 ...
Page 132: ......
Page 163: ...5 FILED WORKING 2019 07 24 SR_CH05_AS004EF_01 ...