Powerful operation
42°C
Indoor heat exchanger
temperature rises
HIGH
Cool air prevention
S-LOW
Indoor heat exchanger
temperature drops
39°C
37°C
30°C
37°C
34°C
32°C
28°C
POWERFUL
LOW
7 minutes later:
42°C
Indoor heat exchanger
temperature rises
HIGH
Indoor heat exchanger
temperature drops
39°C
37°C
30°C
37°C
34°C
32°C
28°C
POWERFUL
LOW
LOW
LOW
•
10 °C HEAT operation
Indoor heat exchanger
temperature rises
Indoor heat exchanger
temperature drops
39°C
34°C
AUTO
LOW
¢
Moisture return prevention control (cooling and dry mode)
Switch the airflow AUTO at cooling mode, and the indoor fan motor will run as shown below.
Compressor
On
Off
Indoor fan
setting airflow
S-LOW
Off
10
30
60
180
60
180
60
10
30
(sec)
Indoor fan speed
3-1. Indoor fan control
- (04-10) -
3. Fan control
CONTROL AND
FUNCTIONS