4. Troubleshooting with error code (For wireless LAN adapter)
4-1. E: 18. External communication error between indoor unit
and WLAN adapter
Indicator
Indoor unit
Operation indicator
1 time flash
Timer indicator
8 time flash
Economy indicator
Continuous flash
Error code
E: 18
Wireless LAN
adapter
LED1 (green)
Flashing fast
LED2 (orange)
On
Detective actuator
Wireless LAN adapter PCB
After receiving a signal from the wireless LAN adapter,
the same signal has not been received for 15 seconds.
NG
Controller
PCB
Controller PCB
Forecast of cause
Connection between indoor unit and wireless LAN
adapter failure
Wireless LAN adapter PCB failure
Controller PCB failure
Check point 1. Check the connection
•
Check any loose or removed connection of between the wireless LAN adapter PCB and con-
troller PCB.
-> If there is abnormal condition, correct it.
•
Check the connection condition on the controller PCB.
-> If there is loose connector, open cable or mis-wiring, correct it.
↓
Check point 2. Replace wireless LAN adapter.
If check point 1 do not improve the symptom, replace the wireless LAN adapter and cancel the reg-
istration of air conditioner on the mobile app.
After replacing the adapter, perform the pairing on the mobile app.
For the method of the mobile app, refer to
↓
Check point 3. Replace controller PCB
If check point 1 to 2 do not improve the symptom, replace the controller PCB.
↓
End
4-1. E: 18. External communication error between indoor unit and WLAN adapter
- (03-63) -
4. Troubleshooting with error code (For wireless LAN adapter)
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for AOTG30KMTC
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2019 06 27 SR_CH01_AS004EF_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 05 12 SR_CH02_AS004EF_05 ...
Page 35: ...3 TROUBLESHOOTING 2020 05 08 SR_CH03_AS004EF_02 ...
Page 38: ......
Page 128: ...6 2 Outdoor unit 03 90 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 129: ...4 CONTROL AND FUNCTIONS 2020 05 08 SR_CH04_AS004EF_02 ...
Page 132: ......
Page 163: ...5 FILED WORKING 2019 07 24 SR_CH05_AS004EF_01 ...