4. Service parts information
4-1. Compressor
Diagnosis method of compressor (If outdoor unit LED displays error, refer to troubleshooting)
Does not start up
Stops soon after starting up
Abnormal noise
Is there open or loose con-
nection cable?
Is there open or loose con-
nection cable?
Check if vibration noise by
loose bolt or contact noise of
piping is happening.
Check main PCB, connection
of compressor, and winding
resistance.
(Refer to the next page)
If there is no failure, the
defect of compressor is con-
sidered (Locked compressor
due to clogged dirt or less oil)
Is gas pipe valve open?
(Low pressure is too low)
Defective compressor can be
considered.
(due to inside dirt clogging or
broken component)
Replace compressor.
Check if refrigerant is
leaking.
MPa
MPa
Replace compressor.
End
Check if strainer is clogged.
(Refer to outdoor EEV in this
chapter.)
End
Check main PCB, connection of compressor and winding resis-
tance. (Refer to the next page)
If there is no failure, the defect of compressor can be consid-
ered. (Compression part broken or valve defective.)
Replace compressor.
End
4-1. Compressor
- (03-43) -
4. Service parts information
TR
O
U
B
LESH
O
O
TI
N
G
TR
O
U
B
LESH
O
O
TI
N
G
Summary of Contents for ADUH09LUAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AR030EF_01 ...
Page 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 17: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AR030EF_01 ...
Page 49: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AR030EF_01 ...
Page 52: ......
Page 110: ...5 2 Outdoor unit 03 58 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 111: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AR030EF_01 ...
Page 145: ...5 FILED WORKING 2021 04 26 SR_CH05_AR030EF_01 ...