15) Outdoor temperature zone boundary temperature B
Setting required if changing of the outdoor temperature setting for heat pump only zone is required
when auxiliary heater control by outdoor temperature 1 is performed on the indoor unit. For details,
refer to “External heater output” in Chapter 0-1. "Details of function" on page 1.
Function number
Setting value
Setting description
Factory setting
67
00
42.8 °F (6 °C)
♦
01
14.0 °F (-10 °C)
02
17.6 °F (-8 °C)
03
21.2 °F (-6 °C)
04
24.8 °F (-4 °C)
05
28.4°F (-2 °C)
06
32.0 °F (0 °C)
07
35.6 °F (2 °C)
08
39.2 °F (4 °C)
09
42.8 °F (6 °C)
10
46.4 °F (8 °C)
11
50.0 °F (10 °C)
12
53.6 °F (12 °C)
13
57.2 °F (14 °C)
14
60.8 °F (16 °C)
15
64.4 °F (18 °C)
16) Standby time for auxiliary equipment operation
Sets the standby time until the auxiliary equipment operation starts during primary equipment opera-
tion.
For details, refer to Chapter 0-1. "Details of function" on page 1.
Function number
Setting value
Setting description
Factory setting
71
00
Disable
♦
01
1 minute
02
2 minutes
•
•
•
•
•
•
98
98 minutes
99
99 minutes
17) Heat pump backup setting
Enables or disables the heat pump backup instruction from the outdoor unit.
This function will be usable provided that the corresponding outdoor unit is connected.
Function number
Setting value
Setting description
Factory setting
72
00
Disable
♦
01
Enable
18) Emergency heat
Enables or disables emergency heat input.
Function number
Setting value
Setting description
Factory setting
73
00
Disable
♦
01
Enable
NOTE:
→hen this function is used, IR receiver unit is necessary.
1-2. Function settings by using remote controller
- (05-9) -
1. Function settings
FI
EL
D
W
O
R
K
IN
G
FI
EL
D
W
O
R
K
IN
G
Summary of Contents for ADUH09LUAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AR030EF_01 ...
Page 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 17: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AR030EF_01 ...
Page 49: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AR030EF_01 ...
Page 52: ......
Page 110: ...5 2 Outdoor unit 03 58 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 111: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AR030EF_01 ...
Page 145: ...5 FILED WORKING 2021 04 26 SR_CH05_AR030EF_01 ...