Sleep timer
If the sleep timer is set, the room temperature is monitored and the operation is stopped auto-
matically. If the operation mode or the set temperature is change after the sleep timer is set, the
operation is continued according to the changed setting of the sleep timer from that time on.
• In the cooling operation mode
→hen the sleep timer is set, the setting temperature is increased 1.8°F (1°C). It increases the
setting temperature another 1.8°F (1°C) after 1 hour. After that, the setting temperature is not
changed and the operation is stopped at the setting time.
Set temperature rises
Ts: Set temperature
Stop of operation
Ts
+3.6
°F (
2°C)
Set
60 min
+1.8
°F (
1°C)
• In the heating operation mode
→hen the sleep timer is set, the setting temperature is decreased 1.8°F (1°C). It decreases
the setting temperature another 1.8°F (1°C) every 30 minutes. Upon lowering 7.2°F (4°C), the
setting temperature is not changed and the operation is stopped at the setting time.
Set
Ts
-3.6
°F (
2°C)
-1.8
°F (
1°C)
-5.4
°F (
3°C)
-7.2
°F (
4°C)
Ts: Set temperature
30 min
30 min
30 min
Stop of operation
Set temperature rises
¢
Weekly timer
On and off timer can be combined, and up to 4 reservations per day and 28 reservations per
week. Before setting the program, set the week and time of the air conditioner at first. If the week
and time are not set, the weekly timer will not operate correctly at the setting time.
4-2. →ired remote control
- (04-19) -
4. Timer operation control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Summary of Contents for ADUH09LUAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AR030EF_01 ...
Page 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 17: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AR030EF_01 ...
Page 49: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AR030EF_01 ...
Page 52: ......
Page 110: ...5 2 Outdoor unit 03 58 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 111: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AR030EF_01 ...
Page 145: ...5 FILED WORKING 2021 04 26 SR_CH05_AR030EF_01 ...