- (01-01) -
M
U
L
T
I T
Y
P
E
2
, 3
, 4 R
O
O
M
S T
Y
P
E
M
U
L
T
I T
Y
P
E
2
, 3
, 4 R
O
O
M
S T
Y
P
E
FEATURES
1.
INDOOR UNIT
1-1.
COMPACT CASSETTE TYPE
1-1-1.
MODELS : AU
G07LVLA, AU
G09LVLA, AU
G12LVLA,
AU
G14LVLA, AU
G18LVLA,
AU
G12LVLB, AU
G14LVLB, AU
G18LVLB
FEATURES
2-stage turbo fan
z
High efficiency design by 2 stage structure
+
2 stage
Previous turbo fan
In the case of a
conventional fan, the air
outlet range was narrow
as the airflow moved to
the motor side which
meant the velocity of air
passing through the heat
exchanger was uneven.
2-stage turbo fan
A evenly spread air distribution across
the heat exchanger is possible due
to the new 2 stage turbo fan which
produces two separate airflow
streams.
Heat exchange
efficiency:
20%UP
1-stage
2-stage
Wind
velocity
Fast
Slow
Easy maintenance
z
Maintenance of fan motor and fan
Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan
can be removed easily.
A : Fan motor B : 2-stage turbo fan
C : Bell-mouth D : Panel
Air filter
: standard equipment
Adaptation of transparent drainage parts
During installation, maintenance and operation, the drain pump and
kit can be checked easily.
Compact design
z
Easy installation by taking off ceiling panel of 600mm x 600mm size
570mm
570mm
High lift drain pump
z
700mm
Quiet quality
z
Optimization of wing form (laminar
wing type) and wing number (7 blades
each)
Airflow runs through smoothly
along the laminar wing
No airflow separation
Adoption of laminar wing
Spin direction
Airflow direction
Quiet
Quiet
Designed by CFD-analysis (fluid) simulations
Laminar wing
A
B
C
D
2
3
1
Grille cover
Summary of Contents for AB*G14LVTA
Page 62: ... 01 58 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE ...
Page 64: ... 01 60 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE Unit mm ...
Page 195: ...2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AO G14LAC2 AO G18LAC2 DTR_AO082E_07 2014 05 30 ...
Page 202: ... 02 06 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 203: ... 02 07 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 WIRING DIAGRAMS 444 MODEL AO G14L2 ...
Page 204: ... 02 08 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 227: ... 02 31 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 SOUND LEVEL CHECK POINT 99999 ...
Page 231: ...3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AO G18LAT3 AO G24LAT3 DTR_AO083E_07 2014 05 30 ...
Page 279: ... 03 47 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 SOUND LEVEL CHECK POINT 99999 ...
Page 283: ...4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AO G30LAT4 DTR_AO078E_08 2014 05 30 ...
Page 289: ... 04 05 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 WIRING DIAGRAMS 444 MODEL AO G30L4 ...
Page 357: ... 04 73 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 SOUND LEVEL CHECK POINT 99999 ...