SPECIFICATIONS
1.
The following performance is a value at standard combinations.
STANDARD COMBINATION
AO
G30LAT4 : AS
G AS
G AS
G AS
G09LMCA
Type
INVERTER MULTI MODELS
HEAT PUMP TYPE
Model name
AO
G30LAT4
Power source
230V ~ 50Hz
Available voltage range
198-264V ~ 50Hz
Capacity
Cooling
Rated
kW
8.0
Btu/h
27300
Min. - Max.
kW
3.5 - 10.1
Btu/h
11940 - 34500
Heating
Rated
kW
9.6
Btu/h
32800
Min. - Max.
kW
3.7 - 12.0
Btu/h
12620 - 41000
Input power
Cooling
Rated
kW
2.22
Max.
3.56
Heating
Rated
2.40
Max.
3.58
Current
Cooling
Rated
A
9.7
Heating
10.5
EER
Cooling
Rated
kW/kW
3.60
COP
Heating
kW/kW
4.00
Starting current
A
10.5
Maximum operating current
A
15.5
Fan
Airflow rate
Cooling
m
3
/h
3500
Heating
3300
Type x Q'ty
Propeller × 1
Motor output
W
103
Sound pressure level *1
Cooling
dB(A)
50
Heating
51
Heat
exchanger
type
Dimension (H × W × D)
mm
798 × 900 × 36.38
Fin pitch
mm
1.3
Rows x Stages
2 × 38
Pipe type
Copper tube
Fin type
Aluminium
Compressor
Type x Q'ty
DC TWIN ROTARY × 1
Motor output
W
1300
Refrigerant
Type (Global Warming Potential)
R410A (1975)
Charge
g
3300
Refrigerant oil
Type
POE
Enclosure
Material
Steel sheet
Colour
BEIGE
(Approximate colour of MUNSELL 10YR7.5 / 1.0NN)
Dimensions
(H ×W ×D)
Net
mm
830 × 900 × 330
Gross
970 × 1050 × 445
Weight
Net
kg
68
Gross
75
Connection pipe
Size
Liquid
mm
Ø6.35 (Ø1/4 in.) × 4
Gas
Ø9.52 (Ø3/8 in.) × 2, *2) Ø12.70 (Ø1/2 in.) × 2
Method
Flare
Pre-charge length (Total)
m
50
Max. length (Total)
70
Max. length (Each)
25
Min. length (Total)
20
Min. length (Each)
5
Max. height difference between
Outdoor Unit and each Indoor Units.
15
Max. height difference between Indoor Units.
10
Operation range
Cooling
°C
0 to 46
Heating
-10 to 24
NOTE:
Specifications are based on the following conditions.
Cooling: Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB / 24 °CWB.
Heating: Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB / 6 °CWB.
Pipe length: 5 m, Height difference: 0 m. (Outdoor unit - indoor unit)
The protective function might work when using it outside the operation range.
*1: These are the measured values in the manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified
values here.
*2: Connect to connection valve by the adapter
Summary of Contents for AB*G14LVTA
Page 62: ... 01 58 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE ...
Page 64: ... 01 60 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE Unit mm ...
Page 195: ...2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AO G14LAC2 AO G18LAC2 DTR_AO082E_07 2014 05 30 ...
Page 202: ... 02 06 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 203: ... 02 07 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 WIRING DIAGRAMS 444 MODEL AO G14L2 ...
Page 204: ... 02 08 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 227: ... 02 31 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 SOUND LEVEL CHECK POINT 99999 ...
Page 231: ...3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AO G18LAT3 AO G24LAT3 DTR_AO083E_07 2014 05 30 ...
Page 279: ... 03 47 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 SOUND LEVEL CHECK POINT 99999 ...
Page 283: ...4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AO G30LAT4 DTR_AO078E_08 2014 05 30 ...
Page 289: ... 04 05 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 WIRING DIAGRAMS 444 MODEL AO G30L4 ...
Page 357: ... 04 73 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 SOUND LEVEL CHECK POINT 99999 ...