3) Outlet directions
Select the appropriate number of outlet directions according to the installation conditions.
(
... Factory setting)
Function number
Setting value
Setting description
22
00
4-way
01
3-way
4) Vertical airflow direction range control
In a concealed installation, change the setting to "Fixed" (02) to restrict the movement of the
upper air outlet so that the airflow is only towards the horizontal direction.
(
... Factory setting)
Function number
Setting value
Setting description
23
00
Standard
01
(Setting prohibited)
02
Fixed (Concealed)
5) Static pressure
Select the appropriate static pressure according to the installation conditions.
(
... Factory setting)
Function number
Setting value
Setting description
26
00
0 Pa
01
10 Pa
02
20 Pa
03
30 Pa
04
40 Pa
05
50 Pa
06
60 Pa
07
70 Pa
08
80 Pa
09
90 Pa
31
25 Pa [Standard]
6) Room temperature sensor control for cooling
Depending on the installed environment, correction of the room temperature sensor may be
required.
Select the appropriate control setting according to the installed environment.
(
... Factory setting)
Function number
Setting value
Setting description
30
00
Standard
01
Slightly lower control
02
Lower control
03
Higher control
In case of Slim duct type and Floor/Ceiling type models: In floor console installations, select
"01".
7) Room temperature sensor control for heating
Depending on the installed environment, correction of the room temperature sensor may be
required.
Select the appropriate control setting according to the installed environment.
(
... Factory setting)
Function number
Setting value
Setting description
31
00
Standard
01
Lower control
02
Slightly higher control
03
Higher control
In case of Slim duct type and Floor/Ceiling type models: In floor console installations, select
"01".
Summary of Contents for AB*G14LVTA
Page 62: ... 01 58 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE ...
Page 64: ... 01 60 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE Unit mm ...
Page 195: ...2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AO G14LAC2 AO G18LAC2 DTR_AO082E_07 2014 05 30 ...
Page 202: ... 02 06 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 203: ... 02 07 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 WIRING DIAGRAMS 444 MODEL AO G14L2 ...
Page 204: ... 02 08 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 227: ... 02 31 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 SOUND LEVEL CHECK POINT 99999 ...
Page 231: ...3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AO G18LAT3 AO G24LAT3 DTR_AO083E_07 2014 05 30 ...
Page 279: ... 03 47 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 SOUND LEVEL CHECK POINT 99999 ...
Page 283: ...4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AO G30LAT4 DTR_AO078E_08 2014 05 30 ...
Page 289: ... 04 05 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 WIRING DIAGRAMS 444 MODEL AO G30L4 ...
Page 357: ... 04 73 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 SOUND LEVEL CHECK POINT 99999 ...