Model name
AS
G07LMCA
AS
G09LMCA
AS
G12LMCA
AS
G14LMCA
Power source
1ø 230V ~ 50Hz
Available voltage range
198-264V
Capacity
2.0kW Class
2.5kW Class
3.5kW Class
4.0kW Class
Input power
W
15
17
22
28
Running current
A
0.13
0.15
0.19
0.25
Fan
Airflow
rate
Cooling
High
m
3
/h
560
600
660
730
Med
500
520
560
600
Low
430
430
450
530
Quiet
310
310
310
360
Heating
High
560
600
660
730
Med
500
520
560
615
Low
430
430
470
560
Quiet
330
330
330
375
Type × Q’ty
Crossflow × 1
Motor output
W
30
Sound pressure level *
Cooling
High
dB (A)
36
37
40
42
Med
32
33
36
38
Low
29
29
30
33
Quiet
21
21
21
25
Heating
High
36
37
40
42
Med
32
33
36
38
Low
29
29
31
35
Quiet
22
22
22
27
Sound power level
Cooling
51
52
54
56
Heating
51
52
55
57
Heat
exchanger
Dimensions
(H × W × D)
mm
Main: 320 × 630 × 20
Sub: 84 × 630 × 13.3
Fin pitch
Main: 1.1, Sub: 1.4
Rows × Stages
Main: 2 × 20, Sub: 1 × 4
Pipe type
Copper tube
Fin type
Aluminium
Enclosure
Material
Polystyrene
Colour
WHITE
(Approximate colour of MUNSELL N9.25)
Dimensions
(H × W × D)
Net
mm
268 × 840 × 203
Gross
270 × 884 × 336
Weight
Net
kg
8.5
Gross
10.5
Connection
pipe
Size
Liquid
mm
Φ6.35 (Φ1/4in)
Gas
Φ9.52 (Φ3/8in)
Φ12.7 (Φ1/2in)
Method
Flare
Drain hose
Material
PP+LLDPE
Size
mm
Φ13.8 (I.D.), Φ15.8 to 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller type
Wireless [Wired (option)]
NOTE:
The protective function may work when using it outside the operation range.
*: These are the measured values in the manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than
the specified values here.
Summary of Contents for AB*G14LVTA
Page 62: ... 01 58 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE ...
Page 64: ... 01 60 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE Unit mm ...
Page 195: ...2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AO G14LAC2 AO G18LAC2 DTR_AO082E_07 2014 05 30 ...
Page 202: ... 02 06 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 203: ... 02 07 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 WIRING DIAGRAMS 444 MODEL AO G14L2 ...
Page 204: ... 02 08 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 227: ... 02 31 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 SOUND LEVEL CHECK POINT 99999 ...
Page 231: ...3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AO G18LAT3 AO G24LAT3 DTR_AO083E_07 2014 05 30 ...
Page 279: ... 03 47 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 SOUND LEVEL CHECK POINT 99999 ...
Page 283: ...4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AO G30LAT4 DTR_AO078E_08 2014 05 30 ...
Page 289: ... 04 05 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 WIRING DIAGRAMS 444 MODEL AO G30L4 ...
Page 357: ... 04 73 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 SOUND LEVEL CHECK POINT 99999 ...