MODEL: AO
G18L2
Cooling
z
Combination
of Indoor Unit
COOLING OPERATION
Cooling Capacity
Input Power
(min-max)
EER
Seasonal Data
Room 1 Room 2
Total Capacity
(min-max)
Pdesign
SEER
Energy
Efficiency
Class
kW
kW
kW
kW
kW
2 Room
7
7
2.10
2.10
4.20 ( 1.7 - 5.2 )
1.24 ( 0.35 - 1.68 )
3.39
4.2
7.0
A++
7
9
2.10
2.50
4.60 ( 1.7 - 5.3 )
1.26 ( 0.35 - 1.79 )
3.65
4.6
6.8
A++
7
12
1.90
3.10
5.00 ( 1.7 - 5.6 )
1.55 ( 0.35 - 1.95 )
3.23
5.0
6.5
A++
7
14
1.80
3.20
5.00 ( 1.8 - 5.7 )
1.55 ( 0.40 - 1.99 )
3.23
5.0
6.5
A++
9
9
2.50
2.50
5.00 ( 1.7 - 5.6 )
1.56 ( 0.35 - 1.95 )
3.21
5.0
6.6
A++
9
12
2.10
2.90
5.00 ( 1.7 - 5.7 )
1.55 ( 0.35 - 1.95 )
3.23
5.0
6.5
A++
9
14
2.00
3.00
5.00 ( 1.8 - 5.8 )
1.55 ( 0.40 - 1.99 )
3.23
5.0
6.4
A++
12
12
2.50
2.50
5.00 ( 1.7 - 5.8 )
1.56 ( 0.35 - 1.99 )
3.21
5.0
6.4
A++
Heating
z
Combination
of Indoor Unit
HEATING OPERATION
Heating Capacity
Input Power
(min-max)
COP
Seasonal Data
Room 1 Room 2
Total Capacity
(min-max)
Pdesign
SCOP
Energy
Efficiency
Class
kW
kW
kW
kW
kW
2 Room
7
7
2.70
2.70
5.40 ( 1.8 - 6.0 )
1.24 ( 0.50 - 1.61 )
4.37
3.8
4.1
A+
7
9
2.50
3.00
5.50 ( 1.8 - 6.0 )
1.36 ( 0.50 - 1.87 )
4.04
4.0
4.1
A+
7
12
2.30
3.30
5.60 ( 1.8 - 6.1 )
1.38 ( 0.50 - 1.88 )
4.06
4.2
4.0
A+
7
14
2.25
3.35
5.60 ( 1.9 - 6.2 )
1.35 ( 0.55 - 1.86 )
4.15
4.2
4.0
A+
9
9
2.80
2.80
5.60 ( 1.8 - 6.1 )
1.41 ( 0.50 - 1.90 )
3.97
4.2
4.1
A+
9
12
2.45
3.15
5.60 ( 1.8 - 6.2 )
1.38 ( 0.50 - 1.88 )
4.07
4.2
4.0
A+
9
14
2.35
3.25
5.60 ( 1.9 - 6.3 )
1.35 ( 0.55 - 1.86 )
4.15
4.2
4.0
A+
12
12
2.80
2.80
5.60 ( 1.8 - 6.3 )
1.34 ( 0.50 - 1.84 )
4.18
4.2
4.0
A+
Notes:
7: 7000Btu/h, 9: 9000Btu/h, 12: 12000Btu/h,14:14000Btu/h models.
•
The above is the value for connecting with Wall Mounted type.
•
2 or more indoor units should be connected.
•
Cooling capacity is based on 27 °CDB / 19 °CWB (indoor temperature), 35 °CDB (outdoor temperature).
•
Heating capacity is based on 20 °CDB (indoor temperature), 7 °CDB / 6 °CWB (outdoor temperature).
•
Pipe length :5m, Height difference :0m. (Outdoor unit to indoor unit)
•
The total capacity of connected a indoor unit is up to 24000 Btu from 14000 Btu.
•
Where "14" means "
•
Wall Mounted type" only models. Other types of indoor units can not be connected.
Summary of Contents for AB*G14LVTA
Page 62: ... 01 58 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE ...
Page 64: ... 01 60 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE Unit mm ...
Page 195: ...2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AO G14LAC2 AO G18LAC2 DTR_AO082E_07 2014 05 30 ...
Page 202: ... 02 06 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 203: ... 02 07 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 WIRING DIAGRAMS 444 MODEL AO G14L2 ...
Page 204: ... 02 08 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Page 227: ... 02 31 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 SOUND LEVEL CHECK POINT 99999 ...
Page 231: ...3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AO G18LAT3 AO G24LAT3 DTR_AO083E_07 2014 05 30 ...
Page 279: ... 03 47 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 SOUND LEVEL CHECK POINT 99999 ...
Page 283: ...4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AO G30LAT4 DTR_AO078E_08 2014 05 30 ...
Page 289: ... 04 05 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 WIRING DIAGRAMS 444 MODEL AO G30L4 ...
Page 357: ... 04 73 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 SOUND LEVEL CHECK POINT 99999 ...