![Fuji Electric PXZ 4 Instruction Manual Download Page 57](http://html1.mh-extra.com/html/fuji-electric/pxz-4/pxz-4_instruction-manual_2341813057.webp)
29
[Description]
• Lower limit (minimum range) and
upper limit (maximum range) of
measurement ranges can be set.
This setting is used as a limiter of
set value (SV). Change of set value
(SV) to others outside of the lower/
upper limit range is not possible.
• When 1 digit below the decimal
point needs to be displayed, it should
be set to 1 by P-dP.
• When P-n2 is set to 0 to 13 (tem-
perature input), up to 1 digit (P-dP
parameter = 1) below the decimal
point becomes effective.
• For the input range, refer to the fol-
lowing table.
Related parameter: P-dP (Page 33)
②
Input range table (standard range)
Example) Altering the measuring range of 0
〜
150
°
C to
-100
〜
200
°
C (Pt100)
Key operation
Description
Press the SEL key for 3 seconds,
and P-n1 is displayed.
Press the SEL key repeatedly until
P-SL is displayed.
Press the or key to display
-100.
Current measuring range is display-
ed.
Press the DATA key. Current
measuring range is displayed.
Press the SV key when you need to
display the operation status display.
After pressing the ENT key, the data
is registered.
Press the or key to display
200.
After pressing the ENT key, the data
is registered.
Display
SEL
SEL
ENT
ENT
SV
DATA
DATA
Pt100
Ω
Pt100
Ω
Pt100
Ω
Pt100
Ω
Pt100
Ω
Pt100
Ω
Pt100
Ω
Pt100
Ω
Measur-
ment range
(
°
C)
Measur-
ment range
(
°
F)
With
decimal
point (
°
C)
With
decimal
point (
°
F)
J
J
K
K
K
R
B
S
T
T
E
E
PL-II
Resistance
bulb
JIS (IEC)
Thermo-
couple
0 to 150
0 to 300
0 to 500
0 to 600
-50 to 100
-100 to 200
-150 to 600
-150 to 850
0 to 400
0 to 800
0 to 400
0 to 800
0 to 1200
0 to 1600
0 to 1800
0 to 1600
-199 to 200
-150 to 400
0 to 800
-199 to 800
0 to 1300
32 to 302
32 to 572
32 to 932
32 to 1112
-58 to 212
-148 to 392
-238 to 1112
-238 to 1562
32 to 752
32 to 1472
32 to 752
32 to 1472
32 to 2192
32 to 2912
32 to 3272
32 to 2912
-328 to 392
-238 to 752
32 to 1472
-328 to 1472
32 to 2372
○
○
○
○
○
○
○
×
○
○
○
○
×
×
×
×
○
○
○
○
×
○
○
○
×
○
○
×
×
○
×
○
×
×
×
×
×
×
×
×
×
×
1 to 5V DC
Direct
current
voltage
-1999 to 1999
(Scaling possible)
Lower limit of measurement range and set value (SV)
(Setting range: -1999 to 9999)
Upper limit of measurement range and set value (SV)
(Setting range: -1999 to 9999)
* For 4 to 20mA DC input, connect external resistor 250
Ω
and
use as 1 to 5V DC input.
Note) Input accuracy is
±
0.5%FS
±
1digit with the exception of
the following.
R thermocouple, 0 to 400
°
C :
±
1%FS
±
1digit
±
1
°
C
B thermocouple, 0 to 500
°
C :
±
5%FS
±
1digit
±
1
°
C
Other thermocouples
:
±
0.5%FS
±
1digit
±
1
°
C