![Fuji Electric FVR-C11S-7EN Series Instruction Manual Download Page 86](http://html1.mh-extra.com/html/fuji-electric/fvr-c11s-7en-series/fvr-c11s-7en-series_instruction-manual_2341873086.webp)
9-2
9 Specifications
FVR-C11S-EN
9
9-2 Common Specifications
Item
Specifications
Braking
Braking torque
5)
[%]
150
100
50
30
DC injection
braking
z
Starting frequency: 3Hz (fixed), Braking current (0 to 100%),
Braking time ( 0.0 to 30.0s)
Protective structure
(IEC60529)
z
Closed type IP20
Cooling method
z
Self-cooling
z
Fan cooling
Mass
[kg]
0.6
0.6
0.7
0.9
1.6
2.2
Notes:
1) A 4-pole standard motor is assumed as a nominal
applied motor.
2) Inverter output capacity (kVA) at 220V.
3) When a momentary power failure occurs, while rated
voltage is applied 85% of load of nominal motor is
given.
4) When an optional power-factor correcting DC reactor is
used.
5) Average braking torque where an unloaded motor
decelerates and stops from 60Hz operation. (Varies
according to the motor efficiency)
6) The specification is calculated on assumption that the
inverter is connected to a 500 kVA-equivalent power
transformer.
Item
Specifications
Remarks
Output frequency
Setting
Maximum
output frequency
z
50 to 120Hz (in 1Hz steps)
Base
frequency
z
50 to 120Hz (in 1Hz steps)
Starting
frequency
z
1 to 6Hz (in 1Hz steps)
Carrier
frequency
z
0.75 to 15kHz
(Vector-distribution PWM control selectable at
7kHz or less)
When operating at a carrier frequency of 9kHz or
above, the frequency may automatically drop to
8kHz to protect the inverter.